SCHY-100V, 200V, 300V, 400V, 500V AC voltage transducer

SCHY-100V, 200V, 300V, 400V, 500V AC voltage transducer

SCHY-100V, 200V, 300V, 400V, 500V

 AC voltage transducer

Input

100V…500V

Output

As per your request

Φ

…mm

Email: sales@zntar.com, zntarjason@gmail.com

More details


AC voltage transducer CHY-100V, 200V, 300V, 400V, 500V

 

Sensor Module

CHY-100V200V300V400V500V

Description

The SENSOR Module CHY-V is an AC voltage transducer to measure 100V…500V (50Hz/400Hz)AC voltages with a galvanic isolation between the primary and secondary circuits. The output of thetransducer is a standard DC signal.

 

AC Voltage TransducerOutput 0…20mA: 

Type

Nominal voltage

Output current

Accuracy

Supply voltage

Aperture

VN(V)

IM(mA)

X(%)

Vc(V)

mm

CHY-100V/A0

100

0…20

±0.5%

15~24

Terminals

CHY-200V/A0

200

 

 

 

 

CHY-300V/A0

300

 

 

 

 

CHY-400V/A0

400

 

 

 

 

CHY-500V/A0

500

 

 

 

 

 

AC Voltage TransducerOutput 4…20mA:

Type

Nominal voltage

Output current

Accuracy

Supply voltage

Aperture

VN(V)

IM(mA)

X(%)

Vc(V)

mm

CHY-100V/A1

100

4…20

±0.5%

15~24

Terminals

CHY-200V/A1

200

 

 

 

 

CHY-300V/A1

300

 

 

 

 

CHY-400V/A1

400

 

 

 

 

CHY-500V/A1

500

 

 

 

 

 

AC Voltage TransducerOutput 0…5V: 

Type

Nominal voltage

Output voltage

Accuracy

Supply voltage

Aperture

VN(V)

VM(V)

X(%)

Vc(V)

mm

CHY-100V/V0

100

0…5

±0.5%

15~24

Terminals

CHY-200V/V0

200

 

 

 

 

CHY-300V/V0

300

 

 

 

 

CHY-400V/V0

400

 

 

 

 

CHY-500V/V0

500

 

 

 

 

 

AC Voltage TransducerOutput 1…5V: 

Type

Nominal voltage

Output voltage

Accuracy

Supply voltage

Aperture

VN(V)

VM(V)

X(%)

Vc(V)

mm

CHY-100V/V1

100

1…5

±0.5%

15~24

Terminals

CHY-200V/V1

200

 

 

 

 

CHY-300V/V1

300

 

 

 

 

CHY-400V/V1

400

 

 

 

 

CHY-500V/V1

500

 

 

 

 

 

Specifications: 

Principle

Transducer

Input voltage

100V…500V(AC)

Output

One of A0=0~20mA、A1=4~20mA、V0=0~5V、V1=1~5V(DC)

Frequency

50Hz(400Hz)

Accuracy

±0.5%

Response time

<0.35S

Linearity

<0.5%

Supply voltage

15V…24V(±5%)

Consumption

30mA+IM(Output current)

Isolation voltage

Between primary and secondary circuit: 6KV RMS/50Hz/1min.

Operating temp.

-25℃ …+85℃

Applications

The sensors are used in the industry field of power supplies, welding machines, converters,

 

industry auto-control, motor drives, electronic power system, railways, rectifiers systems etc.

 

Dimensions(mm) & Connection:    

 

CHY100V