B6 DC Current Transducer
Current cable perforation input, aperture :φ45mm; 0~1200A is optional; Screw fastening installation ; Pull-plug terminal interface...
Current cable perforation input, aperture :φ45mm; 0~1200A is optional; Screw fastening installation ; Pull-plug terminal interface...
*Hall open-loop operational principle, can measure current in any waveform, the output terminal can reflect the waveforms parameters of input current
*Controlled by temperature compensation circuit, measure accurately
*Perforation input, connect terminal,screw fastening plane mounting
*It widely applies to all kinds of industrial current online detection system
*Dimension(mm):102(L)×23(W)×86(H),aperture:45mm;
Specification:
*Standards:GB/13850-1998,IEC688:1992
*Input Range:0~1200A can choose 0~100A,0~1000A etc
*Accuracy Grade :≤1.0%.F.S
*Temperature Characteristics:≤100PPM/℃(0~50℃)
*Power Consumption:≤3.0VA
*Working Stability:annual change<0.2%
*Isolation Withstanding Voltage:AC2.0KV/min*1mA between input/output/power
*Isolation Resistance :≥100MΩ(DC500V)
*Impulse Voltage:5KV(peak value), 1.2/50uS
*Response Time:≤300mS
*Load Capacity:2 times current continuous, 30 times 1 second
*Working Environment :-10℃~50℃,20%~90% without condensation
*Storage Environment :-40℃~70℃,20%~95% without condensation
Model:
A﹍Output |
B﹍Power supply: 5:±12V±10% 6:±15V±10% |
C---Current input range |
Model selection1: LF-DI12-35B6-1.0/0~500A Note:B6 is double power supply |
Dimension:
Connection: