CHB-100KA Closed-loop Hall current sensor
| Name/Model: | Closed-loop Hall current sensor CHB-100KA |
|---|---|
| Rated input Parameter: | 100KA AC、DC、PULSED |
| Name/Model: | Closed-loop Hall current sensor CHB-100KA |
|---|---|
| Rated input Parameter: | 100KA AC、DC、PULSED |
|
Sensor Mod. |
CHB-100KA |
||||
|
Description |
The SENSOR Module CHB-100KA is a closed loop Hall current sensor to measure 100,000ADC, AC or pulsed currents with a galvanic isolation between the primary and secondary circuits. The aperture can be opened by a structure of a split core for easy installation. |
||||
|
Closed-loop Hall Current Sensor: |
|||||
|
Type |
Nominal current |
Output current |
Accuracy |
Supply voltage |
Aperture |
|
IN(A) |
IM(mA) |
X(%) |
Vc(V) |
mm |
|
|
CHB-100KA |
100,000 |
20,000 |
±0.5% |
±48 |
1213x1213 |
|
Specifications: |
|||||
|
Principle |
Closed loop Hall effect principle |
||||
|
Input current |
100,000A(DC、AC、Pulsed current) |
||||
|
Output current |
20,000mA |
||||
|
Turns ratio |
1:5000 |
||||
|
Frequency |
DC~20KHz |
||||
|
Accuracy |
±0.5% |
||||
|
Response time |
<10μS |
||||
|
Linearity |
<0.1% |
||||
|
Supply voltage |
±48V(±5%) |
||||
|
Consumption |
1KW |
||||
|
Isolation voltage |
Between primary and secondary circuit: 10KV RMS/50Hz/1min. |
||||
|
Operating temp. |
-10 …+50℃ |
||||
|
Applications |
The sensors are used in the industry field of power supplies, welding machines, converters, |
||||
|
|
industry auto-control, motor drives, electronic power system, railways, rectifiers systems etc. |
||||


|
||||||||||||||||||||||||||||||||||||||||||||||||
« CHK-2000Y0, 3000Y0, 5000Y0, 8000Y0 Open-loop Hall current sensor CHB-25NP/SP3, SP4, SP5, SP6, SP7, SP8 Closed-loop Hall current sensor »
联系人: 郑先生
sales@transducersgroup.com Skype: zntarjasonCell: 86-15880217206Tel.: 86-592-6220649 Fax: 86-592-6220649